SourceWell Mattress Systems ...................email.............................or call............................ 630-847-3007

Supreme Air™ Mattress System- Model SW9600
Alternating Air Floatation Mattress System

The Supreme AirTM Alternating Pressure Low Air Loss Mattress System combines the most advanced technology and clinically effective features in a portable system. The mattress utilizes 16 independent 8" deep air cells to provide pressure redistribution for the prevention and treatment of Stages I-IV pressure ulcers. User friendly controls and ease of setup make Supreme AirTM ideal for institutional use and the home bound patient. Cover is loose fitting and will conform to the patient. The mattress was designed to fit all standard hospital beds. Supreme AirTM supports patients weighing up to 350 lbs. Supreme AirTM meets California Technical Bulletin #117 for fire retardancy. An optional fire barrier is available to meet the most stringent fire safety requirements when requested.

http://www.bluechipmedical.com/images/imgs/ventilation%20mattress.jpg

http://www.bluechipmedical.com/images/imgs/supreme%20wside.jpg

Bladders:  Ventilated low air loss bladders include 40 air holes in sacral and torso areas to help minimize skin maceration by reducing excess moisture under patient. Air cells are constructed of laminated medical grade nylon and (TPU) thermal polyurethane fabrics. This combination ensures strength, durability and patient comfort.

Shown with optional 9600-SRS  
Foam Side Rail Safety System

Cover:  Vyvex III® multi-directional stretch fabric transfers moisture away from the patient’s skin. The cover is low shear, washable, anti-microbial, fluid resistant and fire retardant. Cover is loose fitting and will conform to the patient.

CPR Valve:  CPR Valve quickly deflates mattress system for medical emergencies. A simple twist releases the air immediately. This multi-purpose CPR Valve can be used to inflate or deflate the mattress with our optional blower pump.

http://www.bluechipmedical.com/images/imgs/supremepump.jpg

PUMP CONTROL UNIT FEATURES: 
Control Unit includes two modes of operation:

  • Alternating 
    Alternating pressure provides the therapeutic  
    benefit of reactive hyperemia and redistributes pressure well below 32mmHg.
  • Static 
    Static mode provides gentle low air loss with constant pressure redistribution and support. This allows nursing to perform patient care.

Control dial adjusts mattress from soft to firm for patient comfort.

Low Pressure Alert and Auto Alarm System offers dual protection to notify caregiver in case of power outages or accidental disconnection of hoses.

http://www.bluechipmedical.com/images/imgs/supreme%20air%20pump%20back.jpghttp://www.bluechipmedical.com/images/imgs/supremeairpumpside.jpg

Deluxe adjustable hanger brackets  
secure control unit to fit all makes of hospital beds.

Easy access filter
reduces damaging dust particles for maintenance free use.

http://www.bluechipmedical.com/images/imgs/faded%20transport.jpg

Transport locking device   insures
mattress remains inflated during a power outage or for patient transport. Reinforced hoses prevent air restriction due  
to kinking.

The optional blower pump can inflate or deflate the mattress through the multi-purpose CPR valve in under four minutes. This reduces waiting time for  
therapeutic treatment to begin.

MODEL 9600

Supreme Air ® - Mattress only

Dimensions:

35" x 80" x 8 "

Weight:

18 lbs.

Air Cells:

16 - 8 " sacs
13 Alternating pressure cells  
10 Low air loss cells with air holes
3 Static cells in head section

Mattress Cover:

Vyvex-III® - Urethane coated, multi-stretch, low shear, moisture/vapor permeable quilted cover. Removable zippered cover, is anti-microbial and meets California Technical Bulletin #117 for fire-retardancy. ?Adjustable anchor straps secures mattress to bed frame.

MODEL 9601

Supreme Air ® - Pump only

Dimensions:

12.5L" x 9W" x 4.5H"

Weight:

7 lbs.

Electrical:

120V 60 hz

Listings:

UL® 544 Medical Equipment

http://www.bluechipmedical.com/images/imgs/electriclogo.jpg

Cycle Time:

10 Minutes

Air Flow:

6.5 - 9.5 Liters per minute

Current Usage:

less than 100 micro amps

Ground Resistance:

0.1 ohms maximum

Power Cord:

12 ft. cord

Construction:

ABS fire retardant UL 94V-0

WARRANTY

Pumps:

1 Year limited

Mattress:

1 year limited

Cover:

6 months limited

ORDERING INFORMATION

 

Model SW9600

Mattress and Pump Control unit

Model SW9601

Pump Control Unit

Model SW9620

Mattress only

Model SW9622

Carry Bag with Strap

Model SW9623

Electric Inflator & Deflator

SADMERC APPROVED

Medicare Code EO277

 

Supreme Air™ meets Group 2 Support Surface requirements for Medicare EO277. Patient must meet all medical criteria to qualify for reimbursement.

 

 

 

 

 

 